top of page

[JABLOTRON] F-LINK SOFTWARE UPDATE: NEW VERSION 3.0.4

12 hours ago
2 min read

F-Link version 3.0.4 officially expands support for the JA-108K control panel, fully integrates system profiles compliant with EN 50131-1 Grade 3 security standards, adds new peripheral devices, and resolves several system bugs to optimize configuration accuracy and improve the user interface experience.


🚀 What's New?

JA-108K support

The JA-108K control panel is now fully integrated into F-Link — including the EN 50131-1 Grade 3 system profile and all accompanying peripheral and system parameter settings.


EN 50131-1 Grade 3 support

The new version introduces a complete system profile for Grade 3 on the JA-108K. It includes:

  • Configuration of peripherals JA-116E, JA-111H TRB, JA-113A and JA-113M to meet the requirements of the standard

  • Monitoring of the minimum required peripheral firmware version

  • Restriction of ARC settings and system parameters of the control panel to comply with the profile

  • New system events:

    • High voltage or current draw on the bus

    • Recording of configuration write failures

    • Recording of "Unknown user" in case of invalid authorisation

  • Exiting service mode is now blocked if an anti-masking fault is active on a detector connected via the JA-111H TRB

  • New behaviour when the maximum number of invalid code login attempts is exceeded

  • Low residual energy indication in JA-113A diagnostics

  • Prohibition of use of identification cards and tags for users

  • New settings section "Advanced settings" in the Parameters tab


New peripherals: JB-112TH and JB-112TP

F-Link 3.0.4 now supports CO₂-measuring thermostats — JB-112TH and JB-112TP.


Minor configuration improvements

  • JA-151R: new parameter "Connection without battery"

  • Additional information added in the authorisation element learning dialog when learning MIFARE-standard elements by presenting a tag

  • JA-156J: parameters "Optical signalling" and "Acoustic signalling" have been merged into one - "Optical and acoustic signalling"; a "Button press signalling" parameter has also been added


What's fixed?

Factory values and default settings

  • JA-112J: incorrect factory value of the "PG control" parameter corrected to "PG on/PG off"

  • JB-128N: factory values for PG outputs and pump protection and anti-freeze protection parameters corrected

  • JB-111TH, JB-111TP, JB-151TH, JB-151TP: incorrect default thermostat values and display in non-Czech language versions corrected

  • JA-112M: settings updated in the EN 50131-1 Grade 2 and Incert profile

  • JA-111H AD TRB: parameters "TMP input" and "LED indication" corrected


False incompatibility reports

  • JA-110R-80 and JA-111R-80 incorrectly reported incompatibility

  • JA-121PB incorrectly reported incompatibility in JA-101K and JA-106K control panels

  • Invalid "Settings do not meet the selected profile" message when exiting service mode on systems with the default profile


User interface fixes

  • JA-156J, JA-157J, JA-154J MS II, JA-152J MS II: schematic icons and object map icons corrected

  • JA-162M: alignment of DIP switch display in the internal settings preview

  • Segment keypads: corrected swapping of A/B lock display on mouse hover

  • Firmware update dialog: persistent "Always on top" priority removed — other windows can now correctly be brought to the foreground

  • Update loop on a new factory-fresh control panel - fixed

  • Incorrect event ordering in the Events from memory dialog - fixed

  • Incorrect LED indication settings for JA-111R, JA-112R, JA-151R - fixed



📥 DOWNLOAD F-LINK SOFTWARE

Technicians and Partners, please click the link below to download the latest installer:


 
 
 

Comments